2200 Series- General purpose industrial pressure transducers.
Gauge, Absolute, Vacuum and Gompound Pressure Models Available
Submersible, General Purpose and Wash Down Enclosures
High Stability Achieved by CVD Sensing Element
Millivolt, Voltage and Current Output Models
The 2200 series features stability and accuracy in a variety of enclosure options. The 2200 and the 2600 feature proven CVD sensing technology, an ASIC (amplified units), and modular packaging to provide a sensor line that can easily accommodate specials while not sacrificing high performance.
Specifications
Input
Pressure Range
Vacuum to 6000 psi (400 bar)
Proof Pressure
2 x Full Scale (FS) (1.5 x Fs for 400 bar, > 5000 psi)
Burst Pressure
>35 x FS <= 100 psi (6 bar);
>20 x FS >= 1000 psi (60 bar);
>5 x FS <= 6000 psi (400 bar)
Fatigue Life
Designed for more than 100 million FS cycles Series 2600
Performance
Long Term Drift
0.2% FS/year (non-cumulative)
Accuracy
0.25 % FS typical (optional 0.15% FS)
Thermal Error
1.5% FS typical (optional 1% FS)
Compensated Temperatures
-5°F to +180°F (-20°C to +80°C)
Operating Temperatures
-40°F to +260°F (-40°C to +125°C) for elec. codes A, B, C, 1
-5°F to +180°F (-20°C to +80°C) for elec. codes 2, D, G, 3
-5°F to +125°F (-20°C to +50°C) for elec. codes FM, P
Amplified units >100°C maximum 24 VDC supply
Zero Tolerance
1% of span
Span Tolerance
1% of span
Response Time
05ms
Mechanical Configuration
Pressure Port
See ordering chart
Wetted Parts
17-4 PH Stainless Steel
Electrical Connection
See ordering chart
Enclosure
316 ss, 17-4 PH ss
IP65 NEMA 4 for elec. codes A,B, C, D, G,1,2,3
IP67 for elec. code “F”
IP68 for elec. codes M, (max depth 200 meters H,0)
1P30 for elec. code “3” with flying leads
Vibration
70g, peak to peak sinusoidal, 5 to 2000 Hz
(Random Vibration; 20 to 2000 Hz @ =~:20g Peak
per MIL-STD.-810E Method 514.4)
Acceleration
100g steady acceleration in any direction 0.032% FS/g
for 15 psi (1 bar) range decreasing logarithmically
10 0.0007% FS/g for 6000 psi (400 bar) range.
Shock
20g, 11 ms, per MIL-STD.-810E Method 516.4 Procedure |
Approvals CE, UR (22IC, 26IC, 22CS, 26CS)