Introducing the cutting-edge Emergency Light Tester, a revolutionary device designed to streamline the testing of your emergency lighting systems. This state-of-the-art time relay brings a host of features to enhance efficiency and reliability in maintaining a safe environment.
Power Supply
Supply Terminals L-N
Supply Voltage AC 230 V (50-60 Hz)
Consumption (Max.) 3.9 VA/1.9 W
Supply Voltage Tolerance -15% ; +10%
Time Circuit
Number of Functions 1
Time Delay (t) 10 m – 30 m – 60 m – 90 m – 120 m – 180 m
Time Setting Rotary Switch
Time Deviation 5% - Mechanical Setting
Repeat Accuracy 0.2% - Set Value Stability
Temperature Coefficient 0.01%/°C, at = 20 °C (0.01%/°F, at = 68 °F)
Output
Contact Type 1× Changeover (AgSnO2); changes the potential "L"
Current Rating 16 A/AC1; 1 HP
Breaking Capacity 4000 VA/AC1, 384 W/DC1
Inrush Current 80 A/20 ms (NO contact)
Switching Voltage 250 V AC/24 V DC
Power Dissipation (Max.) 1.2 W
Mechanical Life 10,000,000 ops.
Electrical Life (AC1) 20,000 ops.
Other Information
Operating Temperature -20 .. +55 °C
Storage Temperature -30 .. +70 °C
Operating Position Any
Mounting DIN Rail EN 60715
Protection Degree IP40 Front Panel / IP20 Terminals
Overvoltage Category III.
Pollution Degree 2
Cross-Wire Section Max. 1× 2.5, 2× 1.5/ Max. 1× 2.5
Dimensions 90 × 17.6 × 64 mm
Weight 53 g
Standards EN 61812-1
Be the first to review this product